Calibrator RS350

RS350 calibrator with tablet

The portable reference standard and calibrator RS350 is especially designed for the needs of metering engineers for on-site testing with high precision.
The equipment offers highest functionality together with excellent menu guided operation through a 8” Tablet PC. 

It’s the perfect instrument to reduce technical- and non-technical losses.

What can I do with this instrument?

The RS350 can perform error measurement for maximum 3 meters at time. The last five individual errors are shown on the tablet together with average error and standard deviation.
The instrument can also detect the meter constant, if the meter is not proper marked.
The tablet gives full information for the testing time, remaining time and shows a progress bar. Instrument transformer ratios can be easy applied.

RS350 error measurement
RS350 error measurement

The RS350 has an internal database for all saved data. The pdf-reports are generated from the database.
Individually imported and exported for synchronisation can be:

  • customer information
  • meter types
  • site information
  • meter test workflows

All test data can be uploaded to a common PC database working under our Electric Measurement Studio platform (EMS5).

RS350 database
RS350 database

The RS350 can check demand registers over a defined time.

The RS350 can perform the analysis for harmonic in voltage & current circuits up to 63rd order. All harmonics are displayed simultaneously on one screen in graphical or table format.
All 6 channels can be stored together.
It’s possible to select the harmonics in percent of the fundamental wave or as total RMS value.

RS350 harmonics
RS350 harmonics

Power harmonics are displayed by phase. Shown is the active, reactive- and apparent content.
RS350 power harmonics
RS350 power harmonics

The RS350 can perform instrument transformer tests. Current transformers can be tested for ratio, phase displacement and burden.
Voltage transformers can be tested for burden.

RS350 CT error
RS350 CT error

RS350 CT burden
RS350 CT burden

RS350 PT burden
RS350 PT burden

The RS350 can record all basic measurement values in cyclic time intervals. The intervals can be set between 1 to 99 seconds. The tablet can store 36,000 records (10 hours with 1 second interval time).

RS350 long time measurement
RS350 long time measurement

RS350 long time measurement settings
RS350 long time measurement settings

The results are displayed in graphical format.
RS350 LTM graph
RS350 LTM graph

The workflow for the meter tester can be defined by the utility. It allows to create systematic meter test sequences. Once the structure is defined, all meter testers will report with the same testing content and nothing will be forgotten. The RS350 guides the user trough all test steps.
The test sequence can include:

  • recording site data
  • verification of proper sealing
  • taking of photos
  • accuracy tests
  • record of the GPS location
  • Signature of witness
  • Report generation
RS350 workflow
RS350 workflow

The RS350 real time measurement display shows all 51 electrically relevant parameters on one screen.
The instrument shows THD & Crest Factor for each phase in voltage & current. It has an easy application of Instrument transformer (IT) ratios for comparison purpose.
Supported are many measurement modes, e.g. 1Ph 2W, 3Ph 3W, 3Ph 4W, in active, reactive & apparent mode, (total & fundamental).
The Apparent power definition is switchable between arithmetical- or trigonometric calculation.

real time measurement
RS350, real time measurement

The RS350 can test energy registers.

The automatic site analysis function of the RS350 checks the essential parameters versus predefined limits and makes wiring checks for the meter tester easier.
Indicated with PASS/FAIL information are:

  • Presence of voltages & currents
  • Direction of currents
  • Balancing of phase voltages & currents
  • Phase symmetry
  • Phase sequence of voltage & current circuits
  • THD in voltage & current circuits
RS350 site analysis
RS350 site analysis

The limits can be set as per utility rules and regulations.

RS350 wiring check limits
RS350 wiring check limits

The RS350 can flexible selected display the actual voltage- and current waveforms for maximum 6 channels in parallel.
Per phase it can show the waveforms of active- and reactive power.
All waves can be saved. To capture suspicious events the RS350 has a HOLD function.

RS350 waveform analysis

The RS350 helps to debug complex wiring problems.

  • Vectorial display along with relevant electrical parameters
  • Automatic hints on the actual wiring status
  • Supports both vectorial presentations (U & I based)
  • Power quadrant display (per phase & total)
wiring check
RS350 wiring check

The calibrator RS350 has a integrated wiring simulator. The simulator can be used for analysis and for training purpose. It can either read the actual values or simulation values.
It’s written in HTML/Javascript and supports most browsers. Take a look here.

RS350 wiring simulation
RS350 wiring simulation

Load More

Specifications

Specifications RS350

Mains and environment

Voltage:


60 V – 265 V AC

Frequency:

47 Hz – 63 Hz

Power consumption:


< 30 VA

Operating temperature:

-5 °C – 50 °C

Max. relative humidity:

≤ 85 %, not condensate

Surge voltage protection:

class C

Installation category:

III

Pollution degree:

2

Ingress protection

IP 30

Housing material

Polycarbonate

Weight:

< 3 kg

Dimensions

268 mm x 243 mm x 68 mm

Measurement parameters

Test voltages, phase-neutral

0.5 V – 576 V

Voltage ranges

60 V, 120 V, 240 V, 480 V, auto range

Test current, direct connected

1 mA – 24 A

Current ranges

20 mA, 50 mA, 100 mA, 200 mA, 500 mA,
1 A, 2 A, 5 A, 10 A, 20 A,
auto-range

Frequency range, fundamental wave

15 Hz – 70 Hz

Bandwidth

4 kHz

Voltage measurement accuracy

< 0.01 %

Voltage measurement drift

< 35 ppm/year

Current measurement accuracy < 25 mA

< 0.02 %

Current measurement accuracy ≥ 25 mA

< 0.01 %

Current measurement drift

< 65 ppm/year

Power measurement accuracy P, Q, S
(related to apparent power)

< 0.05 % (current ≥ 25 mA and λ = 1)

Power measurement drift

< 100 ppm

Phase angle

< 0.01° (current ≥ 25 mA and voltage > 30 V)

Frequency

0.005 Hz

Voltage temperature drift

< 2,5 ppm/K

Current temperature drift

< 5 ppm/K

Power temperature drift

< 7.5 ppm/K

Accessories

Standard accessories

The content of delivery for the calibrator RS350 includes:
10 pcs laboratory cable
4 pcs crocodile clips
10 pcs connector with cable lug
10 pcs adapter with 4 mm pin
10 pcs connector with pin
1 mains power supply cable
10 fuses

The calibrator RS350 has it’s own compartment inside of the transport case. The tablet is for transport safely stored in the case flap.
The actual tablet is a Lenovo TB3-850F. It has 1 GB RAM and 16 GB internal storage. Operation with battery is up to 8 hours.


RS350 case topview
RS350 case topview

The content of delivery for the calibrator RS350 includes 3 pcs. clamp-on CTs. The CLOU clamp-on CT is designed to perform measurements up to 100 A + 20 %. The CT is rated for 600 V ac circuits of Measurement Category III, Pollution Degree 2, per EN/IEC 61010-1 and EN/IEC 61010-2-032.

Specifications
The accuracy classes are related to apparent power. The given accuracy classes are including the internal RS350 error.

Range current Accuracy class
100 A 24 A ≤ 120 A 0.2
20 A 6 A < 24 A 0.2
5 A 1.2 A < 6 A 0.2
1 A 0.24 A < 1.2 A 0.3
0.2 A 0.05 A < 0.24 A 0.5

Mechanical parameters
Can be uses for wiring diameters up to ⌀ 20 mm
Max. Jaw opening 20 mm
Dimensions 53 mm x 138 mm x 28 mm
Weight 350 g
Material PC + ABS + Polycarbonate, UL94 V0

Electrical parameters
Primary current 10 mA – 120 A AC
Max. continuous input current 120 A
Ratio 1200 : 1
Load capacity ≤ 4 Ω
Over voltage category CAT III 600 V
Frequency range 40 Hz – 3800 Hz
Dielectric strength 3 kV 50 Hz / 60 Hz for 1 minute
Temperature range -20 °C – +55 °C
Output 2.0 meter cable with connector for RS350
Max. voltage not insulated conductors 600 V
Compliant with Standards EN/IEC 61010-1, EN/IEC 61010-2-032, IEC60044-1

The documentation for the calibrator RS350 includes:

  • user manual
  • calibration certificate
  • warranty card

This cable adapter is used for accuracy verification of the RS350 against a higher accurate standard (e.g. our reference standard CL3115)

pulse cable
pulse cable

A wired scanning head belongs to the standard scope of delivery for the RS350. It can detect rotor marks for electromechanical meters and pulse diodes for electronic meters. LEDs with a wave-length of 400 – 1100 nm and with pulse frequencies up to 3 kHz can be detected.
The scanning head is delivered with a fixing device. The clamping width is 10 mm to 180 mm.

Scanning Head TP-17C
Scanning Head TP-17C

Bag for scanning head and small parts
Bag for scanning head and small parts

Scanning head specifications

parameter

value

Wave-length

400 – 1100 nm

max. frequency, unmodulated

> 3 kHz

max. frequency, modulated

> 9 kHz

dark to light change

max. 15 µs

light to dark change

max. 15 µs

uncertainty of switching edge detection

±1 µs

pulse width

min. 0.2 ms

operating voltage

3.3 V – 24 V DC

operating current

≤ 50 mA

scanning distance

0 – 50 mm

output signal, high

≥ 3.0 V

output signal, low

≤ 0.3 V

Housing

Polycarbonate

Color

blue-grey

dimensions

30 mm x 46 mm x 22 mm

weight incl. cable

< 80 g

cable length

2 m

ingress protection

IP 54

operating temperature

-40 °C – +85 °C

relative humidity

> 85 %

The equipment is delivered in a trolley with wheels and handle for easy transportation. The trolley is designed in such way that you can leave the RS350 inside and only make the connections to the meter. The cables can remain connected to the RS350 during transport. This saves time and increases the efficiency of use. The suitcase dimensions are 483.5 mm x 474 mm x 237 mm. The weight with standard accessories is less than 12 kg.

Load More

Optional accessories

The basic set of the calibrator RS350 includes one scanning head. Sometimes it’s useful to check the accuracy of two or three energy meters in parallel. The hardware is supporting maximum 3 scanning heads.

Scanning head with fixing device
Scanning head with fixing device

The additional scanning heads are delivered with fixing devices.
Please note that the extension box is needed when using more than one scanning head.
The specifications are the same like the original delivered head.

The RS350 can measure the current in Neutral together with the phase currents.
For Neutral current measurement an additional current clamp is needed.
The specifications are the same like for the 100 A clamps.

The CLOU clamp-on CT is designed to expand the measurement capabilities of CLOU calibrators like RS350 in industrial and power environments to measurements up to 1000 A + 20 %. The CT is rated for 600 V ac circuits of Measurement Category III, Pollution Degree 2, per EN/IEC 61010-1 and EN/IEC 61010-2-032.

clamp-on CT 1000 A
clamp-on CT 1000 A

Specifications
The accuracy classes are related to apparent power. The given accuracy classes are including the internal RS350 error.

Range

current

Accuracy class

1000 A

between 1200 A and 100 A

0.2

100 A

between 100 A and 10 A

0.1

100 A

Between 10 A and 500 mA

0.2


Mechanical parameters

Can be uses for wiring diameters

up to ⌀ 50 mm

Max. Jaw opening

50 mm

Dimensions

103 mm x 220 mm x 28 mm

Weight

550 g

Material

PC + ABS + Polycarbonate, UL94 V0


Electrical parameters

Primary current

0 – 1000 A AC

Max. continuous input current

1200 A

Ratio

2000 : 1

load capacity

≤ 4 Ω

Over voltage category

CAT III 600 V

Frequency range

40 Hz – 3800 Hz

Dielectric strength

3 kV 50 Hz / 60 Hz for 1 minute

Temperature range

-20 °C – +55 °C

Output

2 m cable with connector for RS350

Max. voltage not insulated conductors

600 V

Compliant with Standards

EN/IEC 61010-1, EN/IEC 61010-2-032, IEC60044-1

The CLOU clamp-on CT is designed to expand the measurement capabilities of CLOU calibrators like RS350 in industrial and power environments to measurements up to 2000 A + 20 %. The CT is rated for 600 V ac circuits of Measurement Category III, Pollution Degree 2, per EN/IEC 61010-1 and EN/IEC 61010-2-032.

clamp-on CT 2000 A
clamp-on CT 2000 A

Specifications

The accuracy classes are related to apparent power. The given accuracy classes are including the internal RS350 error.

Range current Accuracy class
2000 A between 2400 A and 600 A 0.1
500 A between 600 A and 120 A 0.2
100 A Between 120 A and 24 A 0.3
20 A Between 24 A and 2 A 0.5
Mechanical parameters
Can be uses for wiring diameters up to ⌀ 50 mm
Max. Jaw opening 75 mm
Dimensions 116 mm x 327 mm x 35 mm
Weight 550 g
Material PC + ABS + Polycarbonate, UL94 V0
Electrical parameters
Primary current 0 – 2400 A AC
Max. continuous input current 2400 A
Ratio 4000 : 1
load capacity ≤ 4 Ω
Over voltage category CAT III 600 V
Frequency range 40 Hz – 3800 Hz
Dielectric strength 3 kV 50 Hz / 60 Hz for 1 minute
Temperature range -20 °C – +55 °C
Output 2 m cable with connector for RS350
Max. voltage not insulated conductors 600 V
Compliant with Standards EN/IEC 61010-1, EN/IEC 61010-2-032, IEC60044-1

The CLOU clamp-on CT is designed to perform measurements up to 5 A + 20 %. The CT is rated for 600 V ac circuits of Measurement Category III, Pollution Degree 2, per EN/IEC 61010-1 and EN/IEC 61010-2-032.

clamp-on CT 5 A
clamp-on CT 5 A

Specifications

The accuracy classes are related to apparent power. The given accuracy classes are including the internal RS350 error.

Range

current

Accuracy class

5 A

2.4 A ≤ 6 A

0.2

2 A

1.2 A < 2.4 A

0.2

1 A

0.6 A < 1.2 A

0.2

0.5A

0.24 A < 0.6 A

0.2

0.2 A

0.12 A < 0.24 A

0.3

0.1 A

0.05 A < 0.12 A

0.3


Mechanical parameters

Can be uses for wiring diameters

up to ⌀ 8 mm

Max. Jaw opening

10 mm

Dimensions

53 mm x 136 mm x 28 mm

Weight

350 g

Material

PC + ABS + Polycarbonate, UL94 V0


Electrical parameters

Primary current

10 mA – 6 A AC

Max. continuous input current

6 A

Ratio

1000 : 1

Load capacity

≤ 4 Ω

Over voltage category

CAT III 600 V

Frequency range

40 Hz – 3800 Hz

Dielectric strength

3 kV 50 Hz / 60 Hz for 1 minute

Temperature range

-20 °C – +55 °C

Output

2.0 meter cable with connector for RS350

Max. voltage not insulated conductors

600 V

Compliant with Standards

EN/IEC 61010-1, EN/IEC 61010-2-032, IEC60044-1

The functionality of the RS350 hardware can be extended to use 3 scanning heads in parallel. For this purpose we have an extension box together with a connection cable to the RS350.

This switch is connected to the pulse input socket of the RS350. It is used to test electromechanical meters under low load conditions.
A scanning head needs about 2 full rotations of the meter disk for adjustment. With the Start-Stop switch you can monitor the mark on the disk. When it is in front, you press the button for starting the measurement. Once the mark arrives again at the front, press the button and see the error result.

start - stop switch
start – stop switch

wireless scanning head
wireless scanning head

The RS350 can work together with one or more wireless scanning heads TP17. This accessory is helpful to test energy meters in parallel without need of extension cables.
See the detailed description here.

Load More

FAQ

Our manual can give only guidance how to use the RS350-Application. For general information of this Android tablet please refer to the original Lenovo instructions.

This is only a short reference for most common meters. Make sure that you have read the RS350 operation manual with more examples.
Always follow your company safety guidelines. In addition it’s no mistake to take a look at our safety regulations.

Single phase 2 wire, DIN terminal
Singlephase two wire meter, DIN terminal
Singlephase two wire meter, DIN terminal
Single phase 2 wire, BS- or ANSI bottom connected terminal
single phase 2 wire, BS terminal
single phase 2 wire, BS terminal

Threephase 3 wire, DIN terminal
DIN threephase 3 wire
DIN threephase 3 wire
Threephase 4 wire, DIN terminal
DIN threephase 4 wire, direct connected
DIN threephase 4 wire, direct connected
Threephase 4 wire CT, DIN terminal
DIN threephase 4 wire CT
DIN threephase 4 wire CT
Threephase 4 wire CT/PT, DIN terminal
DIN threephase 4 wire CT/PT
DIN threephase 4 wire CT/PT

The calibrator RS350 communicates with the Android device (usually the delivered tablet) via Bluetooth. If it’s necessary to pair this two devices new, go to SETTINGS (RS350 application) and select Bluetooth.

RS350 Bluetooth
RS350 Bluetooth

Click on Refresh and select RS350-xxxxxx
The number xxxxxx is matching with the last 6 digits of the RS350 serial no. indicated on the type-label.
The device will show Connected and device battery status as soon as the communication is established.

The calibrators RS350 are leaving our factory with a traceable calibration certificate.
All metrological instruments need to be recalibrated regular. The recalibration period depends on country regulations. In most countries portable calibrators have a recalibration period of one year.
The recalibration can be done in any for this purpose accredited laboratory.
The general principle is to compare the calibrator pulses with the reference standard pulses. Connect the P-OUT to the pulse input and GND to the ground, calculate the meter constant for the actual load and verify the RS350 accuracy with the higher accurate standard.

RS350 meter constants
RS350 meter constants

Load More

Contact Us

Would you like to receive a quotation or to talk to our wonderful sales team? Please enter your email, so we can follow up with you.

Downloads

Specifications in Word-Format

can be used for comparison or tender purpose

Size: 1.2 MB, doc-file
Brochure RS350

Highlights of the portable calibrator RS350.

Size: 12 MB, pdf-file

Training

We are also offering theoretical- and practical training, either in our headquarter in Shenzhen or at customer site.

Isolating Current Transformer CL2030-D

CLOU ICT20-30-D


If a meter has no possibility to open the internal link between voltage and current, the test must be performed with an Isolated Current Transformer (ICT) at each measurement position.
The CL2030-D has a built-in electronic compensation. The ICTs can be remote controlled by PC. A safety protection by controller is built in. This assures that the secondary side is closed in case of high burden or open circuit. Each ICT will be delivered with a company calibration certificate. A certificate issued by an ILAC accredited laboratory is optional available.

ce mark

Specs

Specifications ICT CL2030-D

ItemValue
Nominal Current100 A, max. load 120 %
Ratio1 : 1
Ratio error±0.01 % (0.2 A … 120 A)
±0.03 % (0.05 A < 0.2 A)
±0.05 % (0.01 A < 0.05 A)
Phase displacement±0.3’ (0.2 A … 120 A)
± 3’ (0.05 A < 0.2 A)
± 8’ (0.01 A < 0.05 A)
Max. rated secondary voltage 0.7 V
Max. rated burden for 10 mA ≤ I < 2 A200 mΩ
Max. rated burden for I ≥ 2 A0.7 V / I
Frequency range45 Hz … 65 Hz
Weight:15 kg

accessories

CLOU control box CL2030-3D-CB
The ICTs can operate stand-alone or together with a remote/control by PC. For remote control with 3rd party equipment a control box CL2030-3D-CB is needed. A interface-description is available on request.

This links are uses to interconnect the primary side of ICTs. The copper links are galvanized. This links are designed to connect ICTs with a center to center distance of min 297 mm and max 317 mm.

Load More

FAQ

If you are test equipment manufacturer you can get the ICT2030-D with your company-logo and without any CLOU indication from outside visible.

Principally yes, there must be enough space behind the quick connectors and the source must be powerful enough. Please sent us more information, then we can do a proper integration.

Load More

Contact Us

Would you like to receive a quotation or to talk to our wonderful sales team? Please enter your email, so we can follow up with you.

Wireless Scanning Head for Pulse Detection TP-17

wireless scanning head
wireless scanning head

This scanning head can be used for detection of metrological LED pulse outputs for static electronic meters together with CLOU portable meter test equipment.
The TP-17 Wireless scanning head is based on the Nordic nRF24L01+, highly integrated, ultra low power (ULP) 2 Mbps RF transceiver for the 2.4 GHz ISM (Industrial, Scientific and Medical) band. It includes the Enhanced ShockBurst™ hardware protocol accelerator for a high-speed SPI interface. The no. of TP-17 Wireless scanning heads working in parallel is not limited.

Specs

Specifications scanning head TP-17 Wireless
wavelength 400 …1100 nm
max. sampling frequency 3 kHz
uncertainty of switching edge detection ± 1 μs
pulse width ≥ 0.2 ms
operating voltage 3.3 V DC
scanning distance 10 … 100 mm
housing hard plastic
color blue-grey
dimensions 55 mm x 30 mm x 38 mm
weight < 90 g
transmission power 0 dBm ≙ 1 mW
transmission range, outdoor max. 40 m
transmission range, indoor, industrial environment 25 m (one wall)
battery capacity 800 mAh
permanent operation, battery full charged 72 h
battery charging USB adapter cable
ingress protection IP 54
operating temperature: -40 °C…+85 °C
relative humidity: > 85 %

 

Specifications receiver for scanning head TP-17 Wireless
operating voltage 3.3 V … 5 V DC
operating current ≤ 30 mA
output signal, high ≥ 4.5 V
output signal, low ≤ 0.3 V

accesories


The scanning system consists of

  • Scanning head TP-17 wireless 2.4 GHz transmitter, fixed at the energy meter
  • Fixing device TP-GS 2
    – fastening to meter by two side-plates, can be moved up and down along the meter
    – can be used for rectangle- or round meters
    – adjustable width from 35 to 180 mm
    – provides magnetic adhesion to scanning probes
    – provides mechanical adhesion to scanning probes
    – probes can be moved left/right freely
    – made of insulation material, which ensures safety and portability
  • Receiver TP-17 wireless
  • USB charging cable for scanning head
  • Pairing cable
  • Transport bag

FAQ


ce mark

Yes, the scanning head TP17-wireless is designed and manufactured in conformity with health, safety, and environmental protection standards for products sold within the European Economic Area (EEA). The compliance was verified by MicroTest (external type test laboratory).

Load More

Contact Us

Would you like to receive a quotation or to talk to our wonderful sales team? Please enter your email, so we can follow up with you.

Three Phase Reference Standard CL3115

reference standard CL3115-HW

This reference standard has accuracy class 0.02 related to apparent power
It can be used for

  • voltage measurement
  • current measurement
  • phase angle measurement
  • frequency measurement
  • harmonics analysis up to the 63th
  • power measurement, active-, reactive-, apparent
  • self consumption measurements
  • accuracy error calculations [note]stand-alone with one pulse input socket, or together with error calculators in stationary test benches[/note]
  • register tests
  • Specs

    Specifications Reference Standard CL3115-HW, Mains connection

    Item

    Values

    Voltage

    85 V … 265 V AC

    Frequency

    45 Hz … 65 Hz

    Power consumption

    < 30 VA

    Preheating time

    15 minutes

    Operating temperature

    5 °C … 45 °C

    Max. relative humidity

    ≤ 85 %, not condensate

    Surge voltage protection

    class C

    Installation category

    III

    Pollution degree

    2

    Weight

    approx. 13 kg

    Dimensions

    19” 3 units,
    H x W x D: 132,5 mm x 483 mm x 405 mm

    Specifications Reference Standard CL3115-HW, measurement values

    Item

    Values

    Test voltage, phase-neutral

    30 V … 576 V

    Voltage ranges

    60 V, 120 V, 240 V, 480 V, auto range

    Test current

    1 mA … 120 A

    Current ranges

    10 mA, 20 mA, 50 mA, 0.1 A, 0.2 A, 0.5 A, 1 A, 2 A,
    5 A, 10 A, 20 A, 50 A, 100 A, auto range

    Frequency range, fundamental wave

    40 Hz … 70 Hz

    Bandwidth

    4 kHz

    Voltage measurement accuracy

    < 0.01 %

    Voltage measurement drift

    < 35 ppm / year

    Current measurement accuracy < 25 mA

    < 0.02 %

    Current measurement accuracy ≥ 25 mA

    < 0.01 %

    Current measurement drift

    < 65 ppm / year

    Power measurement accuracy P, Q, S

    < 0.02 % (current ≥ 25 mA and λ = 1)

    Power measurement drift

    < 100 ppm / year

    Phase angle

    < 0.01° (current ≥ 25 mA and voltage > 30 V)

    Frequency

    0.005 Hz

    Voltage temperature drift

    < 2,5 ppm / K

    Current temperature drift

    < 5 ppm / K

    Power temperature drift

    < 7.5 ppm / K

    Errors are independent of measurement mode and when using auto range. The reference standard provides a power proportional frequency output (160 kHz nominal).

    Screen-shots


    The equipment can be operated manually with menu keys or via RS485 remote control. A interface description for integration into 3rd party meter test equipment is available on request. Below are some screen-shots
    PQS
    Power indication in 3 phase 4 wire mode

    UI
    voltage, current, phase angle

    PQS
    Power indication in 3 phase 4 wire mode

    PQS3
    power indication in 3ph 3 wire mode

    accuracy
    accuracy measurement

    Accessories


    scanning head
    transport case

    FAQ

    The recalibration period is defined by national rules or by company policy. Typically it’s one or two years.
    The reference standard can be calibrated by any recognized body or metrological institute.

    Please note that there is a difference between recalibration and readjustment.

    An adjustment becomes necessary once the reference standard accuracy is out of the specified class. The adjustment can be done locally. There is no need to sent the instrument back to us.

    The reference standard CL3115 is by default delivered with a company calibration certificate. It can also be delivered with a calibration certificate issued by an ILAC accredited laboratory on additional cost.

    Following measurement modes are supported by the reference standard CL3115:

    • Three-phase four-wire system, active/ reactive true/apparent
    • Three-phase three-wire system, active/ reactive true/ apparent
    • Single-phase system, active/ reactive true/ apparent
    • Three elements cross connected 90° (Q390)
    • Two elements cross connected 90° (Q290)
    • Two elements cross connected 60° (Q260)

    A frequency proportional to the total power is generated by a signal processor, which applies to the pulse output fOUT of the CL3115. The energy output pulse constant can be set to automatic mode or manual mode. Setting range is: 1…2,000,000,000 i/kWh. The pulse output frequency is 160 kHz for End of range in voltage and current. The energy pulse is on TTL/CMOS level, burden capacity >20 mA. The range can be selected in Auto-mode or direct assigned.
    Calculation formula for the output frequency

     

    Calculation formula for the meter constant

    UR and IR are the ranges, the frequency is 160 kHz

     

    CL3115 meter constants
    3 wire and 4 wire mode
    VOLTAGE RANGE
    60V 120V 240V 480V
    C

    U

    R

    R

    E

    N

    T

    R

    A

    N

    G

    E

    0.01A 2.0×109 2.0×109 2.0×109 2.0×109
    0.02A 2.0×109 2.0×109 2.0×109 2.0×109
    0.05A 2.0×109 2.0×109 2.0×109 2.0×109
    0.1A 2.0×109 2.0×109 2.0×109 2.0×109
    0.2A 2.0×109 2.0×109 2.0×109 2.0×109
    0.5A 2.0×109 2.0×109 1.6×109 8.0×108
    1A 2.0×109 1.6×109 8.0×108 4.0×108
    2A 1.6×109 8.0×108 4.0×108 2.0×108
    5A 6.4×108 3.2×108 1.6×108 8.0×107
    10A 3.2×108 1.6×108 8.0×107 4.0×107
    20A 1.6×108 8.0×107 4.0×107 2.0×107
    50A 6.4×107 3.2×107 1.6×107 8.0×106
    100A 3.2×107 1.6×107 8.0×106 4.0×106

    Load More

    Contact Us

    Would you like to receive a quotation or to talk to our wonderful sales team? Please enter your email, so we can follow up with you.