Scanning Head

A wired scanning head belongs to the standard scope of delivery for the RS350. It can detect rotor marks for electromechanical meters and pulse diodes for electronic meters. LEDs with a wave-length of 400 – 1100 nm and with pulse frequencies up to 3 kHz can be detected.
The scanning head is delivered with a fixing device. The clamping width is 10 mm to 180 mm.

Scanning Head TP-17C
Scanning Head TP-17C
Bag for scanning head and small parts
Bag for scanning head and small parts
Scanning head specifications
parametervalue
Wave-length400 – 1100 nm
max. frequency, unmodulated> 3 kHz
max. frequency, modulated> 9 kHz
dark to light changemax. 15 µs
light to dark changemax. 15 µs
uncertainty of switching edge detection±1 µs
pulse widthmin. 0.2 ms
operating voltage3.3 V – 24 V DC
operating current≤ 50 mA
scanning distance0 – 50 mm
output signal, high≥ 3.0 V
output signal, low≤ 0.3 V
HousingPolycarbonate
Colorblue-grey
dimensions30 mm x 46 mm x 22 mm
weight incl. cable< 80 g
cable length2 m
ingress protectionIP 54
operating temperature-40 °C – +85 °C
relative humidity> 85 %