Multi Secondary Voltage Transformer (MSVT)

Single phase meters with closed I-P links require galvanic isolation for testing.This galvanic isolation is done by a Multi Secondary Voltage Transformer (MSVT). The MSVT has one secondary taping for each meter under test.

The CLOU CL6202-xx can be configured for various secondary tappings. For requests please indicate the no. of meter positions.

item value
No. of windings max. 48
Primary voltage 220 V  –  240 V
Primary frequency 50 Hz  –  60 Hz
Secondary voltage 220 V  –  240 V
Range of secondary burden 4 VA – 15 VA
Accuracy Error prim/sec ≤ ± 0,1%
Phase Error prim/sec ≤ ± 2 min
Accuracy Error sec/sec (within burden range) ≤ ± 0,01%
Phase Error sec/sec (within burden range) ≤ ± 1 min